Schneider Electric Altivar 12 Manual De Usuario

Descargar
Página de 133
BBV28581  05/2010
45
Configuration Mode - MyMenu
Code
Name/Description
Adjustment range
Factory setting
LFr
T
External reference value
-400 Hz to 400 Hz
-
This parameter allows to modify the frequency reference with the jog dial.
External keypad or local force mode configured. 
 pag
 set to 
LCC
 and 
and 
 page 
 different to 
nO
. Visibility depends on the drive settings.
AIU1
T
Analog input virtual
0% to 100%
-
This parameter allows to modify the frequency reference when 
 page 
 is set to 
AIU1
 
• and
 is different to 
nO
.
Visible if reference channel active is integrated display (
 set to 
AIU1
).
bFr
Standard motor frequency
50 Hz
50
60
External keypad or local force mode configured (FLOC = LCC) (not visible in the factory setting).
v
50 Hz 
v
60 Hz
Set to 50 Hz or 60 Hz, taken from the motor rating plate. Changing 
bFr
 sets back parameters: 
FrS
Ftd
 and 
HSP
: 50 Hz or 60 Hz 
itH
 is set to 
nCr
nCr
 according to drive rating
nPr
 Watt or HP
nSP
 according to drive rating
tFr
 60 Hz or 72 Hz
Fr1
Reference channel 1
AI1
AI1
LCC
Mdb
AIUI
This parameter allows selection of the reference source.
v
Terminal
v
Remote display
v
Modbus
v
Integrated display with Jog dial
ACC
T
Acceleration
0.0 s to 999.9 s
3.0 s
Acceleration time between 0 Hz and the 
 page 
Make sure that this value is compatible with the inertia being driven.
dEC
T
Deceleration
0.0 s to 999.9 s
3.0 s
Time to decelerate from the 
 
 pag
 to 0 Hz.
Make sure that this value is compatible with the inertia being driven.
LSP
T
Low speed
0 Hz to HSP
0 Hz
Motor frequency at minimum reference
If 
HSP
HSP2
HSP3
 and 
HSP4
 are already set then 
LSP
 is limited to the minimum of those 
values.
HSP
T
High speed
LSP to tFr (Hz)
50 or 60 Hz 
according to BFr, 
max TFr
Motor frequency at maximum reference.
Check that this setting is appropriate for the motor and the application. The values of 
HSP
HSP2
HSP3
 and 
HSP4
 are idependent but each 
HSP
 value is linked to the values of 
 page 
 according to the following rules:
 
HSP
x is limited to 
 and 
y
HSP
x y
• If 
 is decreased below the current HSPx value, then HSPx  automatically decreases to the new 
value of 
• Once 
HSP
HSP2
HSP3
 and 
HSP4
 are set, 
 is limited to their minimum.
T
Parameter that can be modified during operation or when stopped.