Installation / Assembly
2007 Barbecue Grill and Cart Owner’s Manual 
Page 9
LTR20071038, Rev. B
Natural Gas
Requirements
Always check the rating plate to make sure the gas 
supply you are hooking up to is the gas type the grill is 
manufactured for.
IMPORTANT: Never connect the grill to an unregulated 
gas supply.
The installation of this appliance must conform with 
local codes or, in the absence of local codes, to the 
national fuel gas code, ANSI Z223.1a-1998. Installation 
in Canada must be in accordance with the standard 
CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company 
representative must perform all natural gas 
connections.
Ensure that the service supplying the grill is fitted with a 
shut off valve conveniently positioned near the grill and 
giving ease of access.
The grill must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 0.5 psi 
(3.5 kPa).
The grill and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressure in 
excess of 0.5 psi (3.5 kPa).
Your Cal Flame™ grill for use with natural gas comes 
equipped with its own regulator that MUST NOT 
be removed. If, this regulator needs to be replaced 
use only the type specified by Cal Flame™ for this 
appliance.
Connection
Remove the rear panel from the barbecue to gain 
access to the regulator and gas connection point.
Connect a suitable flex connector to the grill 
regulator.
Check the grill controls to ensure all control valves 
are in the full OFF position.
Turn on the main gas supply and check all 
connections for leaks using soapy water as 
described in the leak testing procedure section.
Warning: If you see bubbles in the soapy solution at 
any of the connections, turn off the gas supply and 
tighten the connection. If tightening the connection 
does not seal the leak, it may be necessary to replace 
the flex hose.
1.
2.
3.
4.