Polycom 3725-74600-004 Manual De Usuario

Descargar
Página de 624
Chapter 20-System Configuration Flags
Polycom, Inc.
20-11
SYSTEM_BROADCAST_VO
LUME
This value is used when the system flag 
FORCE_SYSTEM_BROADCAST_VOLUME is set to YES. 
Determines the default audio level with which the participants 
connects and sends audio to the conference. 
The volume scale is from 1 to 10, where 1 is the weakest and 
10 is the strongest. The default connection value is 5.
Each unit change represents an increase or decrease of 3 dB 
(decibel).
Range: 1-10
Default: 5
SYSTEM_LISTENING_VOLU
ME
This value is used when the system flag 
FORCE_SYSTEM_LISTENING_VOLUME is set to YES. 
Determines the default audio level with which the participants 
connects and receives audio from the conference. 
The volume scale is from 1 to 10, where 1 is the weakest and 
10 is the strongest. The default value is 5. Each unit change 
represents an increase or decrease of 3 dB (decibel).
Range: 1-10
Default: 5
TERMINATE_CONF_AFTER
_CHAIR_DROPPED
From Version 8.1, this flag’s functionality is replaced by the 
Terminate Conference after Chairperson Drops check box 
in the Profile - IVR dialog box. 
In versions prior to 8.1, if YES, sets conferences to 
automatically terminate if the Chairperson disconnects from 
the conference. This takes effect only if the Conference 
Requires Chairperson
 check box in the Conference Profile 
Properties, IVR Tab, is selected.
Default: YES
Note: In order for the "Chairperson Exit" message to be 
played this flag must be set to YES.
USER_LOCKOUT
If YES, a user is locked out of the system after three 
consecutive Login failures with same User Name. The user is 
disabled and only the administrator can enable the user 
within the system. 
Default: NO
USER_LOCKOUT_DURATIO
N_IN_MINUTES
Defines the duration of the Lockout of the user.
Value: 0 - 480
0 means permanent User Lockout until the administrator re-
enables the user within the system.
Default: 0
USER_LOCKOUT_WINDOW
_IN_MINUTES
Defines the time period during which the three consecutive 
Login failures occur. 
Value: 0 - 45000
0 means that three consecutive Login failures in any time 
period will result in User Lockout.
Default: 60
Table 20-1  
System Flags – MCMS_PARAMETERS (Continued)
Flag