Mitsubishi Electronics AJ65BT-D75P2-S3 Manual De Usuario
5 - 36
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
5.2.4 Detailed parameters 2
Item
Setting value, setting range
Default
value
Setting value buffer
memory address
Value set with peripheral device
Value set with
sequence program
Axis 1
Axis 2
Pr.26 Acceleration time 1
The setting value range differs according to the " Pr.25
Size selection for acceleration/deceleration time" setting.
Here, the value within the [Table 1] range is set.
Size selection for acceleration/deceleration time" setting.
Here, the value within the [Table 1] range is set.
[Table 1] on right page
1000
36
37
37
186
187
187
Pr.27 Acceleration time 2
38
39
39
188
189
189
Pr.28 Acceleration time 3
40
41
41
190
191
191
Pr.29 Deceleration time 1
42
43
43
192
193
193
Pr.30 Deceleration time 2
44
45
45
194
195
195
Pr.31 Deceleration time 3
46
47
47
196
197
197
Pr.32 JOG speed limit
value
The setting value range differs depending on the " Pr.11
Stepping motor mode selection" or " Pr.1 Unit setting".
Here, the value within the [Table 2] range is set.
Stepping motor mode selection" or " Pr.1 Unit setting".
Here, the value within the [Table 2] range is set.
[Table 2] on right page
20000
48
49
49
198
199
199
Pr.33 JOG operation
acceleration time
selection
selection
0 : Pr.8 Acceleration time 0
0
0 50 200
1 : Pr.26 Acceleration time 1
1
2 : Pr.27 Acceleration time 2
2
3 : Pr.28 Acceleration time 3
3
Pr.34 JOG operation
deceleration time
selection
selection
0 : Pr.9 Deceleration time 0
0
0 51 201
1 : Pr.29 Deceleration time 1
1
2 : Pr.30 Deceleration time 2
2
3 : Pr.31 Deceleration time 3
3
Pr.26 Acceleration time 1 to Pr.28 Acceleration time 3
Set the item to reach "
Pr.7 Speed limit value" from speed 0 during positioning
operation.
The setting value size is determined by " Pr.25 Size selection for
acceleration/deceleration time".
The setting value size is determined by " Pr.25 Size selection for
acceleration/deceleration time".
Pr.29 Deceleration time 1 to Pr.31 Deceleration time 3
Set the item to reach speed 0 from " Pr.7 Speed limit value" during positioning
operation.
The setting value size is determined by " Pr.25 Size selection for
acceleration/deceleration time".
operation.
The setting value size is determined by " Pr.25 Size selection for