6-4
  
Industio CI-134 Series User’s Manual
Step 9.
 Remove the jumper on position JP1.
jumper
JP1
Remove
Step 10.
 Power on the PC.
ON
Windows NT
This section is specific for troubleshooting under Windows NT. For general problems
and solutions, please see the previous section, “General Troubleshooting”.
1. After  the system r eboots, the er r or  message “Another  dr iver  in the system,
which did not r epor t its r esour ces, has alr eady claimed the inter r upt used by
xxx.” appear s in the Event Log.
This indicates  that  the  MOXA board  is  found,  but the  IRQ  is  conflicting  with
another adapter. Please make sure there is no conflict with other adapter’s IRQ.
Check the BIOS IRQ settings first. Make sure that an IRQ is available.
2. After   the  system  r eboots,  the  er r or   message  “Cannot  find  any  configur ed
MOXA Smar tio/Industio Ser ies boar d!” appear s in the Event Log.
a. Some  partial  decoded  network  board  may  interfere  with  our  board.  Please
avoid from using 0x300 as I/O address for those network boards.
b. Check  hardware  configuration  of 
Industio  CI-134  Series  board  by  IO-
IRQ.EXE.  Then  make  sure  the  hardware  configuration,  including  I/O
addresses for each port, Interrupt Vector, IRQ, is identical to that of the driver.
c. The I/O addresses may conflict with other devices, please change another set
of I/O address such as I/O:0x280, Interrupt Vector:0x2C0.