Troubleshooting
Industio CI-134 Series User’s Manual
  6-5
d. The board(s) is  not plugged properly.  Please make sure  the board is  seated
firmly in the expansion slot.
e. The slot for plugging the board is defective.
In this case, please try other slots until you find a good one.
f.
The board might be defective.
3. The COM number  of the 
Industio CI-134 Series conflicts with others.
The COM numbers of different boards happen to be the same. Try to change the
COM number mappings.
4. Windows NT system panic (blue scr een).
The possible reason is an IRQ or memory conflict with other ISA Bus adapters,
like LAN and SCSI boards, or the system BIOS. Please refer to the corresponding
problem in the previous section, “General Troubleshooting”, for solutions.
Windows 95/98
This  section  is  specific  for  troubleshooting  under  Windows  95/98.  For  general
problems and solutions, please see the previous section, “General Troubleshooting”.
1. The  system  fails  to  find  the 
Industio  CI-134  Series  board!  After  system
r eboot, er r or  message " CI-134 Ser ies (CAP=0x0180, por t 1=COM3): Boar d
is not found"  appear s.
a. Some  partial  decoded  network  board  may  interfere  with  our  board.  Please
avoid from using 0x300 as I/O address for those network boards.
b. Check hardware configuration of CI-134 Series board by IO-IRQ.EXE. Then
make sure the hardware configuration, including I/O addresses for each port,
Interrupt Vector, IRQ, is identical to that of the driver.
c. The I/O addresses may conflict with other devices, please change another set
of I/O address such as I/O:0x280, Interrupt Vector:0x2C0.
d. The board(s) is  not plugged  properly. Please make  sure the  board is  seated
firmly in the expansion slot.
e. The slot for plugging the board is defective.
In this case, please try other slots until you find a good one.
f.  The board might be defective.