Grounding Procedure (For Flammable Materials Only) 
8
3A2090A Operation
Grounding Procedure
(For Flammable Materials Only)
1.
Position striper so that the tires are not on pave-
ment. 
2.
Ground sprayer with grounding clamp. Grounding 
clamp must attach to grounded object (e.g. metal 
sign post).
Pressure Relief Procedure
1.
Perform Grounding Procedure if using flammable 
materials. 
2.
Set pump valve OFF. Turn engine OFF.
3.
Turn pressure control to lowest setting. Trigger gun 
to relieve pressure.
4.
Engage gun trigger safety. Turn prime valve down. 
This equipment must be grounded to reduce the risk 
of static sparking. Static sparking can cause fumes 
to ignite or explode. Grounding provides an escape 
wire for the electric current. 
ti3306a
This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing 
fluid and moving parts, follow the Pressure Relief 
Procedure when you stop spraying and before 
cleaning, checking, or servicing the equipment.