Bradford-White Corp PE2XR504T*F(BN,SX) Manual De Usuario

Descargar
Página de 32
 Page 25 
Gas Control Removal From Thermal Well 
Following the steps below allow for the removal of the gas control from the thermal well 
without removing the thermal well from the tank. 
Step 1. 
Move the gas control power switch to the “OFF” 
position.
Step 2. 
Unplug the water heater and Accessory Module from the 
wall outlet. 
Step 3. 
Turn off the gas supply to the water heater and disconnect 
the gas piping from the gas control. 
Step 4. 
Disconnect the pilot tube 
using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas 
control.
Step 5. 
Disconnect the wire harnesses and spark igniter/
flame sense wire from the gas control.
Step 6. 
Using the gas control service tool, p/n
239-45991-00, available from your BWC parts supplier, insert 
the tool into the back of the gas control. 
Gas Control Removal 
Gas control power 
switch 
Pilot and main 
feedlines 
Spark igniter/flame 
sensor wire 
Gas control
Gas control service 
tool
Water heater power cord and 
Accessory Module transformer 
25