Gas Control Removal From Thermal Well (cont’d)
Step 7. 
Pivot the tool towards the water heater, as far as possible.  Lift straight up 
on the gas control.  The gas control should move about 1/8".  Hold the gas control in 
position and remove the tool.  Lift straight up on the gas control to remove it completely 
from the thermal well.
Gas Control Assembly to the Thermal Well 
Step 1. 
Install the threaded end of the thermal well into the tank. Be sure the 
thermal well flange is positioned properly to allow for proper gas control installation. 
Tighten the thermal well using a 1-5/16” wrench. 
Step 2. 
Route the wire leads back into relief opening. 
Step 3. 
Align the slots located on the thermal well flange 
with the tabs located on the back of the gas control. 
Step 4. 
Carefully push the gas control back onto the thermal well flange as far as 
possible towards the water heater.  Then, slide the gas control down to lock into 
position.
Step 5. 
Install the burner assembly
and connect the pilot and main feedlines
to the gas control using a 7/16” and 3/4” 
wrench, respectively.
Gas Control Removal 
Wire leads on 
thermal well 
Relief opening
Slots in thermal well 
Tabs on back of gas 
control
Pilot and main 
feedlines 
26