Generac Power Systems 009600-5 Manual De Usuario
34 Generac
®
Power Systems, Inc.
6.8.3 BATTERY CABLE CONNECTIONS
1. Connect the battery cable from the battery post or
terminal indicated by a POSITIVE, POS or (+) to the
lug on the starter contactor (Figure 6.20).
lug on the starter contactor (Figure 6.20).
NOTE:
Check to be sure the battery cable boot for the
starter cable has been installed.
starter cable has been installed.
2. Connect the battery cable from the battery post indi-
cated by a NEGATIVE, NEG or (-) to the frame
ground connection (Figure 6.20).
ground connection (Figure 6.20).
3. Connect cables so the connectors are clean
and tight.
Figure 6.20 – Connecting Battery Cables
6.8.4 BATTERY COMPARTMENT
Install the generator battery in its own, vented compart-
ment. Place the battery compartment away from any
source of heat, sparks or flame.
Provide ventilation openings in the battery compart-
ment. The minimum size of openings should be 2
square inches at the top of the compartment. Mount the
battery on a strong, rigid supporting structure, where
leaks and spills of battery fluid will not cause damage.
ment. Place the battery compartment away from any
source of heat, sparks or flame.
Provide ventilation openings in the battery compart-
ment. The minimum size of openings should be 2
square inches at the top of the compartment. Mount the
battery on a strong, rigid supporting structure, where
leaks and spills of battery fluid will not cause damage.
6.9 OPTIONAL
ACCESSORIES
A plug-in receptacle (Figure 6.21) is provided on the
generator set, above the muffler enclosure. Use this
receptacle to connect an optional remote-mounted
start/stop panel to the generator. Installation of such a
panel will permit you to start and stop the generator
engine from any convenient location inside the vehicle.
generator set, above the muffler enclosure. Use this
receptacle to connect an optional remote-mounted
start/stop panel to the generator. Installation of such a
panel will permit you to start and stop the generator
engine from any convenient location inside the vehicle.
Figure 6.21 – Remote Panel Plug-in Receptacle
6.9.1 REMOTE PANEL MODELS
The remote panels mount a rocker type start/stop
switch, a “Generator Run” advisory lamp and an
hourmeter. The hourmeter should be used in conjunc-
tion with the maintenance operations found in Part I of
this manual.
• Model 004057 includes the remote panel and a 10
switch, a “Generator Run” advisory lamp and an
hourmeter. The hourmeter should be used in conjunc-
tion with the maintenance operations found in Part I of
this manual.
• Model 004057 includes the remote panel and a 10
foot long, 4 wire harness.
• Model 004184 includes the remote panel and a 30
foot long, 4 wire harness.
◆
◆
◆
Section 6 – Installation
PRIMEPACT 66G and 66LP Recreational Vehicle Generators
CABLE LENGTH
in Feet (meters)
CABLE SIZE
0 to 10 (0 to 3)
2*
11 to 15 (3.4 to 4.5)
0
16 to 20 (4.5 to 6)
000
*For warm weather, use No. 2 cable up to 20 feet.