E. Electrical Connection
 WARNING
1. Electrical connection must be hard-wired and must meet national, state, and 
local electrical code requirements. Failure to meet these code requirements 
could result in death, electric shock, serious injury, fire, or extensive damage 
to equipment.
2. This unit requires an independent power supply. See the nameplate for 
proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse 
can result in a tripped breaker, blown fuses, or damage to existing wiring. 
This could lead to heat generation or fire.
3. 
THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could 
result in death or serious injury.
4. Electrical connection must be made in accordance with the instructions on 
the "WARNING" tag, provided with the pig tail leads in the junction box. See
Fig. 3.
• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• The white lead must be connected to the neutral conductor of the power source.
CAUTION! Miswiring may result in severe damage to the icemaker. See Fig. 3.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
Fig. 3
115-120/60/1
 WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire 
this unit could result in death, 
serious injury, or severe damage 
to the icemaker. The white lead 
must be connected to the neutral 
conductor of the power source.
See diagram below.
4A4766-010
JUNCTION BOX
115-120V
BROWN
WHITE
L
N