Hoshizaki DCM-751BAH-OS Manual De Usuario

Descargar
Página de 32
18
1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/4" nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Storage bin and drip tray drain outlets are 3/4" FPT. A minimum of 3/4" nominal ID hard
pipe or equivalent is required for the storage bin and drip tray drain lines.
Storage Bin 
Drain Outlet 
3/4" FPT
Drip Tray 
Drain Outlet 
3/4" FPT
Fig. 4
DCM-751BAH(-OS)
Icemaker
Stand
Icemaker Water Supply 
Line Shut-Off Valve
Icemaker Water 
Supply Inlet
1/2" FPT
Icemaker Water Supply 
Line Drain Valve
Vent 
Tube
Minimum 1/4" Nominal ID
Copper Water Tubing 
Minimum 3/4" Nominal ID
Hard Pipe 
Separate piping to approved 
drain. Leave a 2-inch (5-cm) 
vertical air gap between the 
end of each pipe and the 
drain.
2-inch (5-cm) 
air gap
Floor Drain