Condenser Water 
Supply Inlet
1/2" FPT
Condenser 
Drain Outlet 
3/8" FPT
Icemaker Water 
Supply Inlet
1/2" FPT
Drip Tray 
Drain Outlet 
3/4" FPT
2. Water-Cooled Condenser
a) Connection to an Open Drain System 
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/4" nominal
ID copper water tubing or equivalent is required for the condenser water supply line.
• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 1/4" nominal ID hard pipe or equivalent
is required for the condenser drain line.
• In some areas, a back flow preventer may be required in the condenser water supply line.
• In order to maintain the proper high side pressure, the condenser water supply inlet
temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature 
must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation 
is complete, confirm the condenser drain outlet temperature 5 minutes after a freeze 
cycle starts. If the condenser drain outlet temperature is not in the proper range, use a 
flat blade screwdriver to rotate the adjustment screw on the water-regulating valve until 
the temperature is in the proper range (rotate counterclockwise to raise temperature or 
clockwise to lower temperature).
Fig. 5
DCM-751BWH(-OS)
Connection to an Open Drain System
Separate piping to approved 
drain. Leave a 2-inch (5-cm) 
vertical air gap between the 
end of each pipe and the 
drain.
Floor Drain
Icemaker
Stand
Storage Bin 
Drain Outlet 
3/4" FPT
Icemaker Water Supply 
Line Shut-Off Valve
Icemaker Water Supply 
Line Drain Valve
Condenser Water Supply 
Line Shut-Off Valve
Condenser Water 
Supply Line Drain Valve
Vent 
Tube
Minimum 1/4" Nominal ID
Copper Water Tubing 
Vent 
Tube
Minimum 3/4" Nominal ID
Hard Pipe 
Minimum 1/4"
Nominal ID Hard Pipe 
2-inch (5-cm) 
air gap