Crown i-t4000 Guía Del Usuario

Descargar
Página de 48
I-Tech Series Power Amplifiers
Operation Manual
page 21
4 Advanced Operation
Thermal Errors: This screen lets you view thermal errors without using IQwic or Sys-
tem Architect. A thermal error occurs if the amplifier thermal % exceeded the value set 
with the Thermal slider on the Error Reporting Page of the IQwic Control Panel or 
Amplifier Settings in System Architect. 
When an error occurs, the count displayed in this screen is incremented, and the operat-
ing time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will prompt you to confirm 
your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.
Clip Errors: This screen lets you view clip errors without using IQwic or System Archi-
tect. A clip error occurs if the number of clip events exceeds the value set with the Count 
slider
 (within the time set by the Time slider) on the Error Reporting Page of the IQwic 
Control Panel or Amplifier Settings in System Architect.
When an error occurs, the count displayed in this screen is incremented, and the operat-
ing time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will prompt you to confirm 
your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.
Low Limit Load Errors: This screen lets you view low-load errors without using IQwic 
or System Architect. A low limit load error occurs if the load impedance falls below the 
value set with the Low Limit spin control on the Load Monitoring Page of the IQwic 
Control Panel or Amplifier Settings in System Architect.
 When an error occurs, the count displayed in this screen is incremented, and the operating 
time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will prompt you to confirm 
your choice by pressing and holding the Encoder.
NOTE: You must use IQwic or System Architect to enable error reporting and set its limits.
44
44
Low Limit Load Errors
Low Limit Load Errors
32
32
120.1 Hrs
120.1 Hrs
120.1 Hrs
120.1 Hrs
Last
Last
High Limit Load Errors: This screen lets you view high limit load 
errors without using the control software. A high limit load error 
occurs if the load impedance rises above the value set with the High 
Limit  
value on the software Control Panel.
When an error occurs, the count displayed in this screen is incre-
mented, and the operating time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will 
prompt you to confirm your choice by pressing and holding the 
Encoder.
NOTE: You must use IQwic or System Architect to enable error report-
ing and set its limits.
1
High Limit Load Errors
High Limit Load Errors
0
None
None
56.1 Hrs
56.1 Hrs Last
Last
Line Voltage Errors: This screen lets you view line-voltage errors 
without using control software. A line voltage error occurs if the 
line voltage falls outside the values set with the High/Low Limits 
slider
 on the Line Voltage Page of the Control Panel.
When an error occurs, the count displayed in this screen is incre-
mented, and the operating time since the error is displayed. The 
“Low” and “High” indicators show whether the line voltage was below 
or above the line-voltage limits.
To clear this screen, press and release an Encoder. The display will 
prompt you to confirm your choice by pressing and holding the 
Encoder.
NOTE: You must use IQwic or System Architect to enable error report-
ing and set its limits.
Exit: To exit the Monitor Menu and go to the Attenuation screen, 
press Menu/Exit once.
4
Thermal Errors
Thermal Errors
0
None
None
148.3 Hrs
148.3 Hrs
Last
Last
114
114
Clip Errors
Clip Errors
111
111
118.4 Hrs
118.4 Hrs
118.4 Hrs
118.4 Hrs
Last
Last
 14
 14
Line Voltage Errors
Line Voltage Errors
2
70.3 Hrs
70.3 Hrs
6.8 Hrs
6.8 Hrs
Last
Last
LowL
o
w
HighH
i
g
h