4.2.5 Operation Examples
Operation Example 1   
How to set the CH1 input sensitivity using the LCD Control Screen:
1. After power-up, press Menu/Exit. The first menu item appears: 
the Contrast screen.
2. Press Next until you see “CH1 Sensitivity.”
3. Turn an Encoder to set the sensitivity. NOTE: If you do not see 
the sensitivity you want, try changing the Maximum Analog Input 
level (see below).
4. Press Menu/Exit.
Operation Example 2
How to set the Maximum Analog Input level using the LCD Control 
Screen:
1. After power-up, press Menu/Exit. The first menu item appears: 
the Contrast screen.
2. Press Prev until you see “Advanced Menu.”
3. Push an Encoder knob.
4. Press Next
 
until you see “Maximum Analog Input.” 
5. Press an Encoder to change the maximum analog input level.
6. Press Menu/Exit.
Operation Example 3
How to monitor the Thermal Errors using the LCD Control Screen:
1. After power-up, press Menu/Exit. The first menu item appears: 
the Contrast screen.
2. Press Prev. You will see “Monitor Menu.”
3. Push an Encoder knob.
4. Press Next until you see “Thermal Errors.”
4.2.6 Menu Tree
As a handy reference, Figure 4.2 shows the menu structure of the 
LCD control screen. Once you are in a menu, you can loop through 
its selections using the Next and Prev buttons. The Menu/Exit 
button returns you to the Attenuation screen which you see on 
power-up.
You access the Monitor Menu title screen from the Attenuation 
screen by pressing Menu/Exit > Prev. You access the Advanced 
Menu title screen from the Attenuation screen by pressing 
Menu/Exit Prev > Prev.
     MENU TREE
Attenuation - Mute - Lockout
Menu button  
BASIC MENU      
      Contrast (Prev goes to 
                     Monitor Menu)                   
      CH1 Sensitivity
      CH2 Sensitivity
      Presets
      Output Mode
      Input Y
      Me/You Amp Finder
      Advanced Menu screen
      Monitor Menu screen
 
ADVANCED MENU 
(press knob to access these
 items:)   
     Attenuator Limits
     Attenuator Link
     LED Meter Display Type
     Bar Meter Display Type
     Clip Limiter
     Peak Voltage Limiter
     Average Power Limiter
     Pink Noise Generator
     AES/EBU Input Trim
     Input Source
     Maximum Analog Input
     Coarse Signal Delay
     Fine Signal Delay
     Output Polarity
     Bandpass Gain
MONITOR MENU
(press knob to access these
 items:)       
      Load Monitoring
      Thermal %
      AC Voltage
      Operating Time
      Firmware
      Manufacturing Info
      Networking
      Clip Errors
      Thermal Errors
      Low Limit Load Errors
      High Limit Load Errors
      Line Voltage Errors
Next
Prev
Next
Prev
Next
Prev
Exit
Exit
Exit
Figure 4.2 Menu Tree of the I-Tech LCD Control Screen
4 Advanced Operation