Delfield mdbr1-gh Instruccion De Instalación

Descargar
Página de 26
Meridian Series
®
 Reach-Ins Service and Installation Manual
For customer service, call (800) 733-8829 or (800) 733-8948, Fax (989) 773-3210, www.delfield.com
12
Meridian Series
®
 Reach-Ins Service and Installation Manual
13
For customer service, call (800) 733-8829 or (800) 733-8948, Fax (989) 773-3210, www.delfield.com
7
5
T
U
RN
K N B
O
NOON
T
U R
N
KN
B
O
9
TIME
10 11
8
7
6
90
100
80
70
3
1
2
10
2
110
20
30
5
4
6
NIGHT
4
2
3
60
1
10
50
40
11
MID
8
9
TIME POINTER
OUTER
(24 HR.) DIAL
INSIDE
(2 HR.) DIAL
START PIN
BACK-UP 
DEFROST 
POINTER
Paragon 8145
NOTE: The time 
clock dial is 
accessible by 
removing the 
larger plate of 
the electrical box 
located behind 
the removable 
louver.
Removing of the top panel or timer cover may 
expose live electrical parts. Disconnect power 
supply before servicing.
(Figure 1)
Two and three section units only.
Freezer defrost control: All Meridian two door and three door 
freezers are equipped with a Paragon 8145 defrost control for 
automatic defrosting of the evaporator coil. 
To set time of day (Two & three door models only): Grasp 
the knob of the Paragon 8145 time clock dial in the center 
of the inner (2 hour) dial and rotate it in a counter-clockwise 
direction (see figure 1). This will revolve the outer dial. 
Continue turning until the correct time of day on the outer dial 
lines up with the time pointer. This operation requires an initial 
start-up and any time thereafter when there is an interruption 
of power to the freezer.
Operation (Two & Three door models): The Paragon 8145 
timer is preset at the factory to provide four defrosts per day 
at six hour intervals starting at 6:00 am. If it is necessary 
to change the number of defrosts due to unusual operating 
conditions it can be accomplished by placing the pins in 
the outer dial at the appropriate time of the day that defrost 
initiation is desired.
Even under the most severe operating conditions it should not 
be necessary to set the back-up time greater than 60 minutes. 
Consult the factory if complete de-icing of the coil is not 
accomplished within this time period.
PARAGON TIMER CONTROL