Location
Be sure the location chosen has a floor strong enough to 
support the total weight of the cabinet and contents. Units in 
this product line can weigh as much as 1500 pounds when it 
is fully stocked.  Reinforce the floor as necessary to provide for 
maximum loading.
For the most efficient refrigeration, be sure to provide good air 
circulation inside and out.
Inside cabinet: Do not pack unit so full that air cannot circulate. 
Take care not to block air flow to the fans and allow space 
along sides.
Outside cabinet: Be sure that the unit has access to ample 
air. Avoid hot corners and locations near stoves and ovens. 
It is recommended that the rear of the unit be no less than 
two inches from any wall, partition or any other object which 
will restrict exhaust air flow.
Leveling
A level cabinet looks better and will perform better because 
the cabinet will not be subject to unnecessary strain due to 
doors not properly lining up with door frames.
Some models have casters for ease of cleaning underneath 
and for mobility. It is important that the unit be installed in a 
stable condition with the front casters locked before operating. 
Locking the front casters after installation is the owner’s and 
operator’s responsibility.
Electrical connection
A standard self-contained unit is provided with a power cord 
and three-prong grounded plug.
The unit should be plugged into a receptacle with its own 
circuit protection that matches the amperage of the plug.
Refer to the amperage data on page three or the 
serial tag data and your local code or the National 
Electrical Code to be sure the unit is connected 
to the proper power source. A protected circuit of 
the correct voltage and amperage must be run for 
connection to the unit.
The power supply must be disconnected 
whenever performing maintenance or repairing 
the equipment!
The unit must never be operated without the 
louvered panel in place.
Built-in units
All self-contained units (MFSC, FFSC and RFFSC) are tested 
at the factory to assure proper operation. The unit should not 
be installed directly next to high heat generating equipment 
(ranges, griddles, etc.).
These units are built into the counter from below and must 
be supported from the bottom. The counter cut-out sizes and 
power supply requirements are shown in the specifications on 
page three. All refrigerators have drains located in the bottom 
of the tank.  An appropriate drainage area or container must 
be provided by the customer. Be sure to place the unit so the 
pressure control, located near the compressor, can be reached.
For installation of remote units (MF ,FF and RFF), consult a 
refrigeration service company to connect refrigeration lines to 
the remote condensing unit.
Self-contained refrigerated units (MFSC, FFSC 
and RFFSC) require air flow to the compressor. 
A louver is provided and must be installed in the 
counter in front of the condenser. An equal size 
opening at the rear of the cabinet must also be 
provided to allow warm air to escape. Failure to 
do so will void all product warranties.
Free standing units
All self-contained units (N, N6/10/14, NDF, NLFAC, SCF and 
NSCF) are tested at the factory to assure proper operation. The 
unit should not be installed directly next to high heat generating 
equipment (ranges, griddles, etc.).
These units are free standing, either on legs or casters. The 
power supply requirements are shown on page three. All free 
standing units have drains located in the bottom of the tank.  
An appropriate drainage area or container must be provided by 
the customer.
Do not place the unit against a wall or any object that will 
block air circulation through the condensing unit. If the unit 
must be placed against a wall, leave a minimum of 2” of 
space for air flow.
INSTALLATION