Delfield ffsc-2 Instruccion De Instalación

Descargar
Página de 16
Milk, Ice Cream & Milk & Ice Cream Dispensers Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
6
Milk, Ice Cream & Milk & Ice Cream Dispensers Service and Installation Manual
7
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Cleaning the unit
The interior and exterior can be cleaned using soap and 
warm water. If this is not sufficient, try ammonia and water 
or a non-abrasive liquid cleaner.
The lid and lid openings should be cleaned with a sponge 
and mild soap solution on a daily basis to maintain their 
ability to seal.
When cleaning the exterior, always rub with 
the “grain” of the stainless steel to avoid 
marring the finish. Do not use an abrasive 
cleaner because it will scratch the stainless 
steel and plastic.
Do not use a sharp tool or knife to scrape any 
gaskets as this may tear the gasket and ruin its 
ability to seal.
Do not use full strength degreasing agents on 
the gaskets as they could cause the gasket to 
crack and become brittle.
The inside wall of these units house the 
evaporator coil (cooling coil). Never use a 
sharp object to remove frost or ice as this may 
cause the unit to lose its freon charge and will 
void all warranties.
Cleaning the NLFAC milk dispensers
The following special instructions apply to the model NLFAC 
dispenser only. After cleaning the interior and exterior as 
described above, be sure to return the milk case loading 
tray to the bottom of the unit. The load tray is required 
not only for easy self-locating of milk cases, but it also 
ensures proper air flow through the evaporator coil for the 
air curtain.
Any restriction to the air flow path, including 
leaving the milk case load tray out of the 
cabinet, will result in the voiding of your 
warranties.
A drain is supplied to simplify cleaning of the interior. 
Open the clamp used to close off the drain tube. Drain 
accumulated liquid from the cabinet. Be sure to re-clamp 
the tubing before resuming operation of the NLFAC unit.
Honeycomb Cleaning Procedure
Remove the honeycomb material from the equipment.  
Soak in fresh hot dishwater for five minutes.  Rinse by 
spraying soap off with warm water, directing the spray into 
the holes.  Repeat rinsing steps until material is visibly 
clean.  Soak in sanitizing solution for five minutes.  Replace 
into equipment.
Defrosting
If there is 3/8” accumulation of ice formation on the interior 
wall, the unit must be turned off to defrost.
Cleaning the condenser
To maintain peak refrigeration performance, the 
condenser coil fins must be cleaned of dust, 
grease and food particles every 60 days.
If conditions are such that the condenser is totally blocked in 
two months, the frequency of cleaning should be increased.
The condenser can be cleaned with a stiff brush or vacuum 
cleaner. Using high pressure such as compressed air is 
recommended to thoroughly clean the coil.
Failure to follow the recommended methods and 
frequency of condenser coil cleaning will result 
in reduced refrigeration efficiency and possible 
damage to the equipment. It may also invalidate 
your warranties.
Low pressure control settings
The factory recommended low pressure control settings 
for using HFC-134a refrigerant are 30 psig cut-in with a 20 
psig differential. For units using HFC-404A refrigerant, the 
pressure control settings are 30 psig cut-in with a 25 psig 
differential. 
The temperature is controlled by an adjustable pressure 
control located in the machine compartment.  An adjustable 
control has the word COLDER near the knob, with an arrow 
to indicate the adjustment direction.  These controls are 
field adjustable and do not require a service agent.  If you 
have any questions, feel free to contact the Delfield Service 
Department.
In attempting to adjust the pressure control, you can 
do damage to your unit by accidentally adjusting the 
differential.  Please make small incremental adjustments 
if a temperature adjustment is necessary, please contact 
the service department at Delfield (800) 733-8829 #1, or 
your local 
service agent.  
Delfield is not 
responsible 
for charges 
incurred 
while having 
the pressure 
control 
adjusted.
MAINTENANCE