EXTender 3000 System Administrator’s Guide (Definity)
Configuring the Office Module
Page 29
Configuring Data Menu
1.
From the Main Menu, select Configure Data
2.
Press Enter. The Configure Data menu appears.
Setting the Data Type
The EXTender 3000, provides three data communication options (Data Types):
To set the Data Type:
1.
Go to the Configure Data menu.
2.
Select Data Type. Note that the current data type is displayed. 
3.
Press Enter to change the data type.
If Data Type has changed, the Module will display.
Module will Restart if Data Type has Changed? [Y/N]
If you enter N the previous Data Type will be restored.
If you enter Y the new Data Type is saved and the Module will be restarted for the change to take effect.
Details on data operation and configuration are in the Data Communications section of this manual.
Table 5: Data Types
Data Type
Description
Serial
Data is multiplexed with PBX voice connection on one B channel
Dial-up
The second B channel is used to provide a dial-up connection (for use with the 
Dial-up networking feature of Windows 95, 98, NT4.0 and 2000)
Ethernet
The second B channel is used to provide ethernet bridging.
Additional details on data mode configuration are available in the 
section of this 
guide.