Page 30 
EXTender 3000 System Administrator’s Guide (Definity)
Configuring the Office Module
Configuring the COM Port
This option allows you to change the speed of the RS232 port. 
1.
From the Main Menu select Configure Data.
2.
From the Configure Data menu select COM 1. The following sub-menu appears:
Data Rate
Parity
Data Bits
Stop Bits
Exit
Note: All COM port settings should be configured at one time.
Note: The COM Port uses hardware flow control to manage the data throughput. Ensure that the cables and 
network hardware you use have the proper hardware flow control connections to prevent data loss.
Note: The default 9600, 8, N, 1 settings are required when accessing the programming menu after the 8 Yel-
low LED blink sequence is displayed after a unit reboot. The settings as defined above will be used once the 
unit has finished starting up.
Setting Data Rate
To change Data Rate, select Data Rate menu item from COM1 menu.
1.
Highlight the data rate you want. Data rate options are: 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps
2.
Press Enter.
OR
3.
Press the hot key of the data rate you want. When you make your selection, you return to the COM1 
menu.
Setting Parity
To change Parity select Parity menu item from COM1 menu.
1.
Highlight the Parity you want and press Enter. Your choices are None, Even or Odd.
OR
1.
Press the hot key of the Parity you want. When you make your selection, your return to the COM1 
menu.
Setting Data Bits
To change Data Bit select Data Bit menu item from COM1 menu.
1.
Highlight the desired Data Bit and press Enter. Your two options are 8 or 7 data bits.
OR
1.
Press the hot key for the Data Bits you want. When you make your selection, you return to the COM1 