EXTender 3000 System Administrator’s Guide (Definity)
Ethernet Data Type Configuration – Remote
Page 87
Ethernet Data Type Configuration – Remote 
The Remote Module configuration for Ethernet Data Type is similar to the Office Module configuration, 
with some minor differences.
You have the option to configure all Ethernet settings from the Remote phone menus or from the Terminal 
Configuration menu. This section will refer to the Remote Terminal menu configuration for the Ethernet 
Configuration.
Remote Module Ethernet parameters that require configuring are:
Data Phone Number
Point-To-Point Protocol
Bridging
The following Remote Module Ethernet parameters are optional 
Point-To-Point Protocol – Data-on-demand 
Note: you must also program DN/MSN1 and DN2/MSN2 in the Configure ISDN menu for Ethernet to work 
correctly.
Data Phone Number
Under the Configure Data menu on the Remote Terminal menu there is an additional sub-menu, Data Num-
ber. 
The Data Phone Number is used to specify the phone number that the remote extender will call to establish 
the PPP connection for bridging data. If the remote is calling an office extender, this number should be that 
configured as DN2 on the office Module. If the data ISDN connection is to some other remote access device, 
it should be the appropriate phone number for that device
The Data Phone Number can also be programmed from the Set Dial Numbers phone menu
Configure PPP
With the exception of the Data-On-Demand configuration, the PPP configuration parameters for the remote 
extender are identical to those specified above for the office extender. Refer to the appropriate sections in the 
Ethernet Configuration–Office Module for information on these parameters. 
Of course, on the remote, the parameters can be configured via the phone instead of the terminal menu.
Data-On-Demand Mode
The Remote extender provides a Data-On-Demand (DOD) feature that will bring down the ISDN data con-
nection after a specified period of “inactivity”. The actual definition of inactivity is dependent upon the 
DOD mode selected.
DOD may reduce costs by connecting the line only when data is being transmitted.
Disabled (Default)– if DOD is disabled, then the ISDN connection will remain active until one of 
the extender’s is powered off or the connection is brought down manually via the Ethernet manage-
ment console. If the Remote unit is dialing to some other remote access device instead of a switch 
extender, it is also possible for the other device to terminate the connection.
Transmit Only- In this mode, as long as a system attached to the Ethernet port on the remote