Citel 3000 Guía De Instalación

Descargar
Página de 48
EXTender 3000 Quick Installation Guide
Norstar/Meridian - Installing the Office Module
Page 25
Installation Procedure
All connections to the Office Module are done via the back panel.
Figure 8: Norstar/Meridian Office Module Back Panel
1.
Connect the ISDN BRI line from your PBX or a central office (CO) line to the ISDN jack of the Office 
Module at the on-premise location. Use the RJ45 cable, included with the system.
Ensure you connect an ISDN ST interface Office Module to ST interface line or an ISDN U interface 
Office Module to U interface line. A quick way to check the type of ISDN interface on your office mod-
ule is to determine which way the line leads on your RJ45 cable are pointing if you were to insert the 
cable into office module. The cable line leads point “up for U” (point down for ST). The U interface 
connector is orientated the same as the digital port and Ethernet connectors.
2.
Connect the Office Module SWITCH jack to the 2-wire digital port on the PBX using a standard phone 
cable.
3.
If you are using Ethernet data, connect the Ethernet jack on the Office Module to the Ethernet jack at the 
on-premise location. Use a standard Ethernet cable. Refer to the Data Configuration section of the Sys-
tem Administrator’s Guide to set the Ethernet data type operation.
4.
If you are using Serial or Dial up data, connect the RS-232 jack on the Office Module to the on-premise 
PC or Data Communications Server. Use a straight-through RS-232 cable. You may need an adapter if 
your equipment does not have a 9-pin connector. Refer to the Data Configuration section of the System 
Administrator’s Guide to set the Ethernet data type operation.
5.
Connect the AC adapter to an electrical outlet. Use only the AC adapters provided with the Extender. U 
interface requires a 120v AC adapter, an S/T interface requires a 220/240v AC adapter.
6.
The Office Module starts powering up. After a long series of flashing LED sequences, the Office Mod-
ule LED will blink a repeating series of yellow, green, *green, red. This LED sequence confirms that the 
Office Module is installed correctly. 
*Note: For an S/T Interface, the third blink may not be green.
Ethernet
Jack
ISDN Jack
Electrical
Outlet
Switch
Ethernet
RS-232
ISDN +12VDC
RJ45 Digital Line
RJ45 Cable
Serial Cable
RJ45 Cable
AC Adapter
PBX or Key System
U Interface
S/T Interface