EXTender 3000 Quick Installation Guide
Norstar/Meridian - Configuring the Office Module
Page 27
Norstar/Meridian - Configuring the Office Module
Pre-Configuration Checklist
Ensure that the installation procedure for the Office Module has been completed, and all cables are con-
nected correctly. Please refer to Figure 1 for installation.
Configuration Procedure
The PC must be running a VT100 terminal emulation communication application. The Office Module can 
run in one of the three Data types: Serial, Ethernet and Dial-up (default). For more information about these 
data types, see the EXTender  3000 System Administrator’s Guide.
For U interface units you must program the SPID numbers and the numbers for your ISDN line. For S/T 
interface you can configure the MSN numbers if required.
For basic operation of S/T interface units (no data) there is no need to change the default settings pro-
grammed in the EXTender. Refer to the EXTender 3000 System Administrator’s Guide for directions on 
configuring the EXTender for data operation.
Accessing the Terminal Configuration Menu
For all data types:
1.
To access the configuration menu for the Office Module, you must connect a terminal or PC to the RS-
232 port of the Switch Module.
The PC must be running a terminal emulation package. Configure your terminal or terminal application 
to 9600bps, No parity, 8 data bits, and 1 stop bit. The terminal type should be set to VT100.
2.
Unplug the Office Module, and plug it back in after waiting a few seconds.
When the Office Module is powered up, a specific boot blink sequence is observed, after approximately 
60 sec. it will blink three sets of 8 yellow flashes.
3.
Type the word MENU from your PC or terminal while the LED blinks its first set of 8 yellow flashes, 
described above. The Configuration menu will appear.
For dialup data type only:
If your Module’s data type is Dial-up (the factory default data type) you can access terminal configuration at 
any time from the AT command mode. 
1.
To access the configuration menu you must connect a terminal or PC to the RS-232 port of the Office 
Module. The PC must be running a terminal emulation package with terminal type set to VT100.
2.
Configure your PC COM port settings to match the Office Module.The factory default COM port set-
tings for dial-up data types are: 57600 bps, No parity, 8 data bits, and 1 stop bit. If this has been changed 
set your PC to use the current settings or use the Power-up Access Method (optional).
From the AT command mode type AT@MENU followed by a RETURN key from your PC. The Con-
figuration menu will appear.
For Ethernet data type only:
If your Module’s data type is Ethernet you can access terminal configuration at any time from the Ethernet 
Console.