Citel 3000 Guía De Instalación
EXTender 3000 Quick Installation Guide
Norstar/Meridian - Configuring the Office Module
Page 27
Norstar/Meridian - Configuring the Office Module
Pre-Configuration Checklist
Ensure that the installation procedure for the Office Module has been completed, and all cables are con-
nected correctly. Please refer to Figure 1 for installation.
nected correctly. Please refer to Figure 1 for installation.
Configuration Procedure
The PC must be running a VT100 terminal emulation communication application. The Office Module can
run in one of the three Data types: Serial, Ethernet and Dial-up (default). For more information about these
data types, see the EXTender 3000 System Administrator’s Guide.
run in one of the three Data types: Serial, Ethernet and Dial-up (default). For more information about these
data types, see the EXTender 3000 System Administrator’s Guide.
For U interface units you must program the SPID numbers and the numbers for your ISDN line. For S/T
interface you can configure the MSN numbers if required.
interface you can configure the MSN numbers if required.
For basic operation of S/T interface units (no data) there is no need to change the default settings pro-
grammed in the EXTender. Refer to the EXTender 3000 System Administrator’s Guide for directions on
configuring the EXTender for data operation.
grammed in the EXTender. Refer to the EXTender 3000 System Administrator’s Guide for directions on
configuring the EXTender for data operation.
Accessing the Terminal Configuration Menu
For all data types:
1.
To access the configuration menu for the Office Module, you must connect a terminal or PC to the RS-
232 port of the Switch Module.
232 port of the Switch Module.
The PC must be running a terminal emulation package. Configure your terminal or terminal application
to 9600bps, No parity, 8 data bits, and 1 stop bit. The terminal type should be set to VT100.
2.
Unplug the Office Module, and plug it back in after waiting a few seconds.
When the Office Module is powered up, a specific boot blink sequence is observed, after approximately
60 sec. it will blink three sets of 8 yellow flashes.
60 sec. it will blink three sets of 8 yellow flashes.
3.
Type the word MENU from your PC or terminal while the LED blinks its first set of 8 yellow flashes,
described above. The Configuration menu will appear.
described above. The Configuration menu will appear.
For dialup data type only:
If your Module’s data type is Dial-up (the factory default data type) you can access terminal configuration at
any time from the AT command mode.
any time from the AT command mode.
1.
To access the configuration menu you must connect a terminal or PC to the RS-232 port of the Office
Module. The PC must be running a terminal emulation package with terminal type set to VT100.
Module. The PC must be running a terminal emulation package with terminal type set to VT100.
2.
Configure your PC COM port settings to match the Office Module.The factory default COM port set-
tings for dial-up data types are: 57600 bps, No parity, 8 data bits, and 1 stop bit. If this has been changed
set your PC to use the current settings or use the Power-up Access Method (optional).
tings for dial-up data types are: 57600 bps, No parity, 8 data bits, and 1 stop bit. If this has been changed
set your PC to use the current settings or use the Power-up Access Method (optional).
From the AT command mode type AT@MENU followed by a RETURN key from your PC. The Con-
figuration menu will appear.
figuration menu will appear.
For Ethernet data type only:
If your Module’s data type is Ethernet you can access terminal configuration at any time from the Ethernet
Console.
Console.