Jiffy j-1 Guía Del Usuario

Descargar
Página de 84
29
Jiffy
®
J-4000 Cleaning Instructions
The cleaning procedure below is recommended as a regular maintenance
measure to help your steamer maintain its maximum steaming performance.
This maintenance should be performed on a basis of every 3-6 months
depending on your water supply. In most cases, a steamer that is severely
clogged will require disassembly to properly clean and prolong the life span of
the unit. An authorized repair center or a Jiffy® Steamer service technician best 
performs this disassembly. 
1.  Remove hose attachment from unit at the brass coupling using a wrench.
Pour out any remaining water from your unit. 
2. If the hose attachment is blocked by sediment build-up, use a water hose to
clean inside the hose. This should loosen and remove any build-up that may
have occurred within the hose itself. 
3.  To clean the internal parts of your steamer, use of the Jiffy® Liquid Cleaner
(10 ounce bottle) is recommended. This acid-based cleaner will remove hard
water deposits and sediment build-up. This cleaner is not available for
export. 
4.  Fill your steamer with 1 gallon of water and add the entire ten (10) ounce
bottle of Jiffy® Steamer Liquid Cleaner. Turn the steamer to PREHEAT and
allow water and solution to warm. 
5.
When the red pilot light goes off, indicating the end of the PREHEAT
cycle, turn the switch to OFF and unplug the steamer from the wall outlet.
Allow the water and cleaning solution to remain in the steamer for 3 hours.
DO NOT STEAM THE SOLUTION IN THE UNIT AS DAMAGE MAY
OCCUR. 
6.  Pour the cleaning solution out of the steamer. Do this by tipping the steamer
over and pouring the solution out of the brass fitting where your hose
attachment normally connects. 
7.  Rinse the unit thoroughly by flushing with fresh water 3 times. 
8.  If discolored water or residue continues to come from the unit, the above
procedure may need to be repeated. 
9.  Please call 1-800-525-4339 or 731-885-6690 for further instructions or
questions.