Panasonic DBS 576 Manual Suplementario

Descargar
Página de 370
Section 700 - Operation
Chapter 7. SLT Features
576-50-700
DBS 576HD (USA) issued September 2001
5-71
Meet-Me Answer
To answer a page using Meet-Me Answer:
Hardware Requirements
External relays, amplifier, and speakers are required for external paging.
Related Programming
FF1-0-02: Paging Override
FF1-0-03: Extension COS (Paging)
FF1-0-04: Trunk COS (Paging)
FF1-2: Dial Plan
FF2: Trunk COS
FF3: Extension COS
Considerations
You can assign the paging access code to a one-touch or FF key. Beginning with Version 3.5 and 
higher, the assigned FF key LED indicates whether the paging system is in use. If the paging 
system is not in use when a page is originated, the FF key LED lights solid green on the 
originator’s telephone. If someone in the paging group initiates a page, assigned FF key LEDs on 
all other telephones will light solid red until the page has been terminated. 
If an external paging system has been connected, pages can be made to paging groups 0-9 
through the external speakers. Voice paging can also be heard over the extensions in groups 0-9.
An extension can belong to more than one paging group.
Only one page may be performed at a time. If you attempt to make a page while another 
extension is paging, you will receive a busy signal unless your system allows Paging Override.
Beginning with Version 3.5 and higher, the paging system can be set to “timeout” if a page 
remains unanswered for a specified length of time (0 to 255 seconds). If this feature is set and the 
timeout period has elapsed, the page originator’s handset will emit a Fast Busy Tone and the 
words “Paging Time Out” will be displayed on the originating telephone’s display.
Action
Result
1.   Lift the handset or press the ON/OFF key.
Intercom dial tone
2.   Enter the Meet Me Answer code (default = ##).
Connected to specified party