3com 5500-ei pwr Guía De Referencia

Descargar
Página de 1314
 
1-22 
Parameters 
value: Interval to send trap messages, in the range 5 to 3600 (in seconds). 
Description 
Use the lldp timer notification-interval command to set the interval to send trap messages. 
Use the undo lldp timer notification-interval command to restore the default.  
By default, the interval to send trap messages is 5 seconds.  
Examples 
# Set the interval to send trap messages to 8 seconds. 
<Sysname> system-view 
[Sysname] lldp timer notification-interval 8 
lldp timer reinit-delay 
Syntax 
lldp timer reinit-delay value 
undo lldp timer reinit-delay 
View 
System view 
Parameters 
value: Initialization delay period to be set, in the range 1 to 10 (in seconds). 
Description 
Use the lldp timer reinit-delay command to set the initialization delay period. 
Use the undo lldp timer reinit-delay command to restore the default. 
By default, the initialization delay period is 2 seconds. 
Examples 
# Set the initialization delay period to 4 seconds. 
<Sysname> system-view 
[Sysname] lldp timer reinit-delay 4 
lldp timer tx-delay 
Syntax 
lldp timer tx-delay value 
undo lldp timer tx-delay 
View 