3com 5500-ei pwr Guía De Referencia
1-27
user-interface
Syntax
user-interface [ type ] first-number [ last-number ]
View
System view
Parameters
type: User interface type, which can be AUX (for AUX user interface) and VTY (for VTY user interface).
first-number: User interface index identifying the first user interface to be configured. A user interface
index can be relative or absolute.
z
In relative user interface index scheme, the type argument is required. In this case, AUX user
interfaces are numbered from AUX0 through AUX7; VTY user interfaces are numbered from VTY0
through VTY4.
z
In absolute user interface index scheme, the type argument is not required. In this case, user
interfaces are numbered from 0 to 12.
last-number: User interface number identifying the last user interface to be configured. The value of this
argument must be larger than that of the first-number argument.
Description
Use the user-interface command to enter one or more user interface views to perform configuration.
Examples
# Enter VTY0 user interface.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] user-interface vty 0
[Sysname-ui-vty0]
user privilege level
Syntax
user privilege level level
undo user privilege level
View
User interface view
Parameters
level: Command level ranging from 0 to 3.
Description
Use the user privilege level command to configure the command level available to the users logging in