3com 7000 Manual Suplementario

Descargar
Página de 516
Setting the Timers
403
Set Retransmit
Interval
Sets the retransmit interval. The retransmit interval is the time after which 
unacknowledged PTSEs will be retransmitted. A change to the retransmit 
interval takes place after the next reboot.
Command Actions
Command Result
Example
Enter: 
1 1 10 4 3 4 7 1
The following message is displayed:
Default Value is 5, new value is 1
Press ENTER to continue...
Enter menu sequence: 
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(7) RTI: Retransmit Interval
Enter a parameter at the prompt
Parameter
Format or Range
interval
1 - 60000 seconds
Direct access sequence:
1 1 10 4 3 4 7 
[parameters]
System action taken:
The retransmit interval is displayed and is updated to 
its new value.
System message display:
Default value is <x>, new value is <y>