3com 7000 Manual Suplementario
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
420
C
HAPTER
13: C
ONFIGURING
AND
M
ANAGING
PNNI (F
OR
THE
E
XTENDED
V
ERSION
O
NLY
)
Set Optimization for
ABR
Updates the Available Bit Rate (ABR) optimization parameter. A change to
the ABR optimization parameter takes place immediately.
the ABR optimization parameter takes place immediately.
Command Actions
Command Result
Example
Enter:
1 1 10 4 3 5 2 4 4
The following message is displayed:
Default Value is ‘3 - opt_ctd’, New value is ‘4 - opt_ctv’
Press ENTER to continue...
The value of the ABR optimization parameter is updated to 4.
Enter menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(5) OPT: Optimization Metrics
(2) SOP: Set Optimization
Metrics
(4) OAR: Optimization for ABR
Enter a parameter at the prompt
Parameter
Format or Range
constant bit rate
0 - 6
Direct access sequence:
1 1 10 4 3 5 2 4
[parameters]
System action taken:
The ABR optimization parameter is displayed and is
updated to its new value.
updated to its new value.
System message display:
Default value is <x>. New value is