3com 7000 Manual Suplementario

Descargar
Página de 516
430
C
HAPTER
 13: C
ONFIGURING
 
AND
 M
ANAGING
 PNNI (F
OR
 
THE
 E
XTENDED
 V
ERSION
 O
NLY
)
Set UBR
Administrative
Weight
Sets the UBR Administrative Weight parameter. The UBR administrative 
weight is the administrative weight of this interface port for the 
unspecified bit rate service category.
Command Actions
Command Result
Example
Enter: 
1 1 10 4 4 2 6 18000
The following message is displayed:
Default value is 5040, new value is set to 19000
Press ENTER to continue...
Enter menu sequence: 
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(4) ICF: Interface Configuration
(2) IPR: Interface Parameters
(6) UBW: UBR Admin Weight
Enter a parameter at the prompt
Parameter
Format or Range
UBR admin weight
1 - 2147483647
Direct access sequence:
1 1 10 4 4 2 6 
[parameters]
System action taken:
The UBR admin weight parameter is updated to its 
new value.
System message display:
Default Value is 5040, New value is set to <n>.