3com 7000 Manual Suplementario
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
Setting Interface Parameters
431
Set RCC Service
Category
Sets the RCC service category parameter.
The RCC service category is the
service category used for the PNNI routing control channel (VCI = 18) on this
interface.
interface.
See Table 54 for an explanation of the service category
parameters.
Command Actions
Command Result
Example
Enter:
1 1 10 4 4 2 7 2
The following message is displayed:
Default value is 6, new value is set to 2
Press ENTER to continue...
Enter menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(4) ICF: Interface Configuration
(2) IPR: Interface Parameters
(7) RSC: RCC Service Category
Enter a parameter at the prompt
Parameter
Format or Range
RCC service category
2
- cbr
3
- rtVbr
4
- nrtVbr
5
- abr
6
- ubr
Direct access sequence:
1 1 10 4 4 2 7
[parameters]