The CoreBuilder 7000 family power supplies are shown in Table 19.
Power Supply
Operation
Load Sharing
The power supplies can operate in load-sharing mode; two 90A power 
supplies can produce up to 180A. Providing that the power consumption 
of the unit does not exceed 90 A, load-sharing allows one power supply 
to serve as a backup. 
Overloading
When the installed power supply is rated for less than the required power 
consumption of the CoreBuilder module, the CoreBuilder will not 
succeed in powering up. It will attempt to power up, hit the current 
overload rate and turn the power supply off, going through this cycle 
repeatedly until the load is reduced. 
Calculating the Power
Consumption of
CoreBuilder Switch
The power consumption of an entire CoreBuilder 7000 family ATM switch 
unit is calculated by adding up the power consumption of the switching 
card(s) and interface cards installed in the chassis. Normally, the values for 
typical power consumption can be used in the calculation. Table 20 
shows the typical power consumption values for the CoreBuilder 7000 
family ATM switching cards and interface cards.
Table 19   CoreBuilder 7000 Family Power Supplies
Power Supply
Current
3Com 
Number
CoreBuilder 7000/7000HD AC Power Supply
90A
3C37010A
CoreBuilder 7000/7000HD DC Power Supply
90A
3C37027
CoreBuilder 7000/7000HD DC Power Supply
40A
3C37026
Table 20   Typical Power Consumption of CoreBuilder 7000 Family Cards
Component Description
3Com 
Number
Typical
*
 Power 
Consumption 
(Amp) 
CoreBuilder Kit and Switching Card
CoreBuilder 7000 Kit (one switching card and 
one power supply)
3C37000
6.3
CoreBuilder 7000 Redundant Switching Card
3C37016
6.3
CoreBuilder 7000HD Kit (one switching card and 
one power supply)
3C37001
8.1