3com S7906E Guía De Referencia

Descargar
Página de 2327
 
3-1 
3  
Alarm Configuration Commands 
 
 
 
An alarm command executed in FTTH view will take effect on all the OLT ports of the system or all 
the ONUs under the OLT;  
 
An alarm command executed in OLT port view will take effect on the current port and all the ONUs 
under it;  
 
An alarm command executed in ONU port view will take effect only on the ONUs under the port.  
 
Alarm Configuration Commands 
alarm bit-error-rate 
Syntax 
alarm bit-error-rate { direction { uplink | downlink | up-down-link } | threshold threshold } 
undo alarm bit-error-rate { direction | threshold } * 
View 
OLT port view, FTTH view 
Default Level 
2: System level 
Parameters 
uplink: Specifies the monitor direction. Only uplink data will be monitored. 
downlink: Specifies the monitor direction. Only downlink data will be monitored. 
up-down-link: Specifies the monitor direction. Both uplink and downlink data between OLT and ONU 
will be monitored. 
threshold  threshold: Specifies the alarm threshold of bit error rate. The threshold  argument ranges 
from 1 to 10
9
 and defaults to 10 (in 10
-9
). 
 
Description 
Use the alarm bit-error-rate command to configure the monitor direction and the alarm threshold of the 
bit error rate.  
Use the undo alarm bit-error-rate command to restore the default monitor direction and alarm 
threshold.