Configuring a modem 
adaptation baud rate
Networking requirement
On the asynchronous interface connected to the modem, use a standard AT 
command to configure the modem baud rate, and send the “AT” command to 
the modem. If “OK” is received from the modem, it indicates that the modem can 
automatically adapt to the corresponding baud rate. Then, write the configuration 
into the modem for conservation, and the corresponding AT command is 
“AT&W”.
Networking diagram
Figure 267   Network of the configuration for the router to manage the modem
Configuration procedure
Configure a modem script.
[3Com]script-string baud "" AT OK AT&W OK
Execute the corresponding script in interface view, supposing the modem is 
connected to the interface tty1. Using the 
display user-interface tty 1
 
command to see the absolute index be 1.
<3Com> start-script baud 1
Restoring the ex-factory 
modem settings
Configuration requirement
To restore the ex-factory modem settings, use the “AT&F” command.
Configuration procedure
[3Com]script-string factory "" AT OK AT&F OK
<3Com> start-script factory 1
Power-on Initialization 
through the 
Initialization Script
Configuration requirement
Enable the router to initialize the Modem to which the asynchronous interface is 
connected when powering on the router or rebooting it.
Configuration procedure
[3Com]script-string init "" AT OK AT&B1&C1&D2&S0=1 OK AT&W OK
[3Com]user-interface tty1
[3Com-ui-tty1]modem
[3Com-ui-tty1]script trigger init init
Dialling Directly with 
the Script 
Configuration requirement
Configure a Modem script to dial directly.
Configuration procedure
[3Com]script-string dial "" AT OK ATDT8810058 CONNECT
PC
PSTN
Router
Modem