Polycom EX Manual De Referencia

Descargar
Página de 150
Chapter 6 - Testing and Troubleshooting
© Polycom, Inc.
111
Indicator Lamps on the Quad BRI Network Interface Module
The Quad BRI network interface module uses pairs of indicator 
lamps associated with each BRI line to provide status indications. 
The table below shows the meanings of the LED pair associated with 
one line. Note that the lines in use may not always display the same 
status. If this is the case, you should investigate the cause. .
Red and yellow 
LEDs on
Receiving clock sync, and receiving AIS Alarm 
Indication Signal (unframed all-ones)
Green LED on
System  fully synchronized with the network and 
ready to use
Table 6-2.  PRI indicator lamps - Peripheral side
Lamp behavior
Meaning
Amber LED on
Booting (brief) or starting software update (over 
60 seconds)
Amber and green 
LEDs on
Software update in progress
Green LED on
Ready
a
a. If the PRI network interface module is connected to an external 
power source, the green LED turns on after several seconds, even 
if the peripheral link cable is not connected.
Table 6-3.  Quad BRI Indicator Lamps
Indication
Meaning
Green LED
Off = no connection to the switch, or no clock
On = clock is synchronized with the switch
Yellow LED 
Off = in reset mode, booting
On = active
Both LEDs on
Normal operation
Table 6-1.  PRI indicator lamps - Network side (Continued)
Lamp behavior
Meaning