14.  Maintenance, Troubleshooting
14-2
14.2
Fuses
The MFD has a fuse that protects the MFD from high electric current and equipment 
fault. If you cannot turn on the power, check the fuse to see if it has blown. Find the 
reason for the blown fuse before you replace the fuse. If the fuse blows again after the 
replacement, contact your dealer for information. A wrong fuse can damage the equip-
ment.
Fuse information
14.3
The Magnetron
When the life of the magnetron is reached, the targets do not appear on the radar dis-
play. If long-range performance appears to have decreased, contact a FURUNO 
agent or dealer about replacement of the magnetron.
Magnetron information
Name
Type
Code No.
Remarks
Fuse
FGB0-A 125V 5A PBF
000-155-853-10
For MFD8, 24V
Fuse
FGB0 125V 10A PBF
000-155-826-10
For MFD8, 12V
Fuse
FGB0 125V 10A PBF
000-155-826-10
For MFD12, 24V
Fuse
FGB0 125V 20A PBF
000-155-780-10
For MFD12, 12V
Radar Sensor
Magnetron
Code No.
DRS2D
E3590
000-164-574-10
DRS4D
E3571
000-146-867-00
DRS4A
MAF1421B
000-158-786-10
DRS6A
MAF1422B
000-158-788-10
DRS12A
E3566
000-164-418-10
DRS25A
MG5436(E2V)
000-140-762-10
WARNING
Use the proper fuse.
A wrong fuse can damage the equipment
and cause fire.