SERVICE (cont.)
CONTROL THERMOSTAT
Location:
The control thermostats are located inside the
trunk on the left side of the component brackets.
Test Procedures:
1. Disconnect the brewer from the power source.
2. With a voltmeter, check the voltage across the
1. Disconnect the brewer from the power source.
2. With a voltmeter, check the voltage across the
blue wire on the control thermostat and the
white insert on three pole 120/240 volt terminal
block and the red insert on two wire 200 volt ,240
volt or the three wire three phase 230 volt terminal
block. Connect the brewer to the power source.
The indication must be:
white insert on three pole 120/240 volt terminal
block and the red insert on two wire 200 volt ,240
volt or the three wire three phase 230 volt terminal
block. Connect the brewer to the power source.
The indication must be:
a) 120 volts ac for three wire 120/240 volt mod-
els.
els.
b) 200 volts ac for two wire 200 volt models.
c) 240 volts ac for two wire 240 volt models.
d) 230 volts ac for three wire, three phase 230 volt
models.
models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wiring
Diagrams and check the brewer wiring harness.
4. Gently remove the capillary bulb and grommet
If voltage is not present as described, refer to the Wiring
Diagrams and check the brewer wiring harness.
4. Gently remove the capillary bulb and grommet
from the tank.
5. With a voltmeter, check the voltage across the black
wire of the control thermostat and the white insert
on the three pole 120/240 volt terminal block and
the red insert on the two pole 200 volt,240 volt
or the three wire three phase 230 volt terminal
on the three pole 120/240 volt terminal block and
the red insert on the two pole 200 volt,240 volt
or the three wire three phase 230 volt terminal
block when the control thermostat is turned fully
clockwise. Connect the brewer to the power source.
The indication must be:
clockwise. Connect the brewer to the power source.
The indication must be:
a) 120 volts ac for three wire 120/240 volt mod-
els.
els.
b) 200 volts ac for two wire 200 volt volt models.
c) 240 volts ac for two wire 240 volt models.
d) 230 volts ac for three wire three phase 230 volt
models.
models.
6. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capillary
tube into the tank to the line 4.5" above the bulb, the
control thermostat is operating properly.
If voltage is not present as described, replace the ther-
mostat.
If voltage is present as described, reinstall the capillary
tube into the tank to the line 4.5" above the bulb, the
control thermostat is operating properly.
If voltage is not present as described, replace the ther-
mostat.
Removal and Replacement:
1. Remove wires from control thermostat leads.
2. Remove the thermostat capillary bulb by fi rmly
1. Remove wires from control thermostat leads.
2. Remove the thermostat capillary bulb by fi rmly
pulling up on the capillary at the tank lid. This will
disengage the grommet from the tank lid.
disengage the grommet from the tank lid.
3. Remove the one #8-32 screw securing the control
thermostat to the component bracket in the trunk.
4. Slide the grommet to the line 4.5" above the bulb
on the new capillary tube.
5. Insert the capillary bulb through the hole in the tank
lid and press the grommet fi rmly and evenly so that
the groove in the grommet fi ts into the tank lid.
the groove in the grommet fi ts into the tank lid.
6. Carefully bend the capillary tube so that the tube and
bulb inside the tank are in the vertical position.
NOTE - The capillary tube must be clear of any electrical
termination and not kinked.
7. Using one #8-32 screw secure the control thermostat
to the component bracket inside the trunk.
8. Refer to Fig. 3 when reconnecting the wires.
9. Adjust the control thermostat as required.
9. Adjust the control thermostat as required.
FIG. 2 CONTROL THERMOSTAT
P2197
10737 120800
P1129
FIG. 3 CONTROL THERMOSTAT LEADS
BLU to BLU Lead from
Limit Thermostat
Limit Thermostat
BLK to BLK Lead from Tank Heater
(Brewers W/Out Faucet)
BLK to BLK Fused Lead from Tank
Heater (Brewers with Faucet)
(Brewers W/Out Faucet)
BLK to BLK Fused Lead from Tank
Heater (Brewers with Faucet)