Location:
 
The ON/OFF switchs are located on the front of the 
hood.
ON/OFF SWITCHES 
SERVICE (cont.)
LIMIT THERMOSTAT
Location:
 
The limit thermostats are located inside the rear 
of the hood on the center rear of the tank lids.
Test Procedures:
1.  Disconnect the brewer from the power source.
2.  Disconnect the blue and black wires from the limit 
thermostat.
3.  With an ohmmeter, check for continuity across 
the limit thermostat terminals.
If continuity is present as described, the limit thermostat 
is operating properly.
If continuity is not present as described, replace the 
limit thermostat.
Removal and Replacement:
1.  Remove all wires from limit thermostat terminals.
2.  Carefully slide the limit thermostat out from under 
the retaining clip and remove limit thermostat.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to Fig. 5 when reconnecting the wires.
P1800
FIG. 4 LIMIT THERMOSTAT
P2197
FIG. 6 ON/OFF SWITCH
P2489.20
BLK to Tank 
Heater Switch
BLU to BLU Lead from 
Control Thermostat
10737 100801
FIG. 5 LIMIT THERMOSTAT TERMINALS
2/2 Models
4/2 Models
0/6 Models
APS Models
0/2 Models