SOLENOID VALVE (DISPENSE) - FMD-4 & FMD-5
FIG. 31 DISPENSE SOLENOID VALVE
Location:
 
The dispense solenoid is located on the upper left 
center of the tank.
Test Procedures:
1.   Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect the two wires from the solenoid valve 
that is being tested. With the “RINSE/RUN” switch 
in the “RINSE” upper  position press the  dispense  
switch on front of the door.
3.  Check  the  voltage  across  the  two  wires  with  a 
voltmeter.  Connect  the  dispenser  to  the  power 
source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt, and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect  the  dispenser  from  the  power 
source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to wiring 
diagram and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve 
coil terminals.
If continuity is present as described, reconnect the  
wires to the solenoid (see Fig. 32), proceed to #6
If continuity is not present as described, replace the 
solenoid valve.
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. With “RINSE/RUN” 
switch in the “RINSE” upper position press the 
dispense switch and listen carefully in the vicinity 
of the solenoid valve for a “clicking” sound  as the 
coil magnet attracts.
7.  Disconnect  the  dispenser  from  the  power 
source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water outlet before the solenoid valve or, 
the solenoid valve may require inspection for wear, 
and removal of waterborne particles.
If the sound is not heard as described, replace the 
solenoid valve.