FIG. 34 INLET SOLENOID VALVE TERMINALS
SERVICE (cont.)
WHI from Main Harness
7.  Disconnect  the  dispenser  from  the  power 
source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If the sound is not heard as described, replace the 
solenoid valve.
Removal and Replacement:
1.  Remove the white and violet wires from the solenoid 
valve.
2.  Turn-off the water supply to the dispenser.
3.  Disconnect the water lines to and from the solenoid 
valve.
4.  Remove the two #8-32 screws securing the sole-
noid to the rear of the dispenser housing. Remove 
solenoid. 
5.  Remove the two #8-32 U-Type fasteners from the 
solenoid bracket.
6.  Install the two #8-32 U-Type fasteners and the two 
#8-32 screws on the new solenoid.
7.  Install new solenoid on rear of dispenser housing 
and tighten the two screws
8.  Securely fasten the water lines to and from the 
solenoid valve.
9.  Refer to Fig. 34 and reconnect the wires.
VIO from Main Harness
SOLENOID VALVE (INLET)
FIG. 33 INLET SOLENOID VALVE
Location:
 
The inlet solenoid is located on the lower left side 
near the rear panel.
Test Procedures:
1.   Disconnect  the  dispenser    from  the  power 
source.
2.  Disconnect  the  white  and  violet  wires  from  the 
solenoid valve. 
3.  Check  the  voltage  across  the  white  and  violet 
wires with a voltmeter. Connect the dispenser to 
the power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt, and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect  the  dispenser  from  the  power 
source,
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the wiring 
diagram and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If continuity is present as described, reconnect the 
white and violet wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
P2635
6.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source.  Listen carefully 
in the vicinity of the solenoid valve for a “clicking” 
sound  as the coil magnet attracts.
35135 100407