SERVICE (cont.)
Removal and Replacement:
1.  Disconnect the wires from the rectifier.
2.  Remove the #10-32 screw securing the rectifier 
to the motor mounting bracket.
3.  Remove the rectifier and discard.
4.  Install  new  rectifier  on  the  rear  of  the  motor 
mounting  bracket  and  secure  with  a  #10-32 
screw.
5.   Refer to Fig. 13 and reconnect the wires. 
BLK from Motor (+)
BLU to BLU from Motor (AC)
WHI from Main Harness (AC)
RED from Motor (-)
FIG. 13 RECTIFIER TERMINALS
P1381
RECTIFIER - G1MD ONLY
FIG. 12 RECTIFIER
P1706
Location:
 
The  rectifier  is  located  inside  the  grinder 
housing mounted on the rear of the motor mounting 
bracket.
Test Procedures:
1.   Disconnect the grinder from the power source.
2.  Remove the red wire and the black wire from the 
rectifier.
3.  Check the voltage across the (+) and (-) terminals 
on  the  rectifier  with  a  voltmeter.  Connect  the 
grinder to the power source and start the grinder 
motor. The indication must be approximately 108 
volts dc.
4.  Disconnect the grinder from the power source.
If voltage is present as described, the rectifier is op-
erating properly.
If  voltage  is  not  present  as  described,  refer  to  the 
grinder wiring diagram and check the grinder wiring 
harness.
10191 011500