Bunn Single SH Guía Del Usuario

Descargar
Página de 44
Page 17
FIG. 5 BREW SELECTOR SWITCH
P1388
SERVICE (cont.)
BREW SELECTOR SWITCH (cont.)
Removal and Replacement:
1. Disconnect the connector on the selector switch
harness from the brewer timer circuit board.
2. Disconnect wires from the selector switch, inter-
face socket, dispense valve and bypass valve.
3. Loosen the set screw on the switch knob.
4. Remove  the  9/16"  nut  and  washer  holding  the
switch to the hood.
5. Remove the switch.
6. Install the new switch. The positioning tab must be
in the hole in the hood for proper switch and knob
alignment.
7. Install the knob so that the arrow lines up in the  1-
1/2  or  1-3/4  gallon  position  when  the  switch  is
turned to the full right position.
8. Reattach the connector to the brew timer circuit
board.
9. Refer to Fig. 5  when reconnecting the wires.
28230 092200