Bunn Single SH Guía Del Usuario
Page 19
Location:
The limit thermostat is located inside the hood on
the tank lid just to the left of the tank heater.
Test Procedure:
1. Disconnect the brewer from the power supply.
2. Disconnect both black wires from the limit ther-
1. Disconnect the brewer from the power supply.
2. Disconnect both black wires from the limit ther-
mostat.
3. Check for continuity across the limit thermostat
terminals with a ohmmeter.
If continuity is present as described, reconnect the
black wires to the limit thermostat , the limit thermo-
stat is operating properly.
If continuity is not present as described, press the
reset button on the limit thermostat and repeat step
#3.
After repeating step #3 and no continuity is shown,
replace the limit thermostat.
black wires to the limit thermostat , the limit thermo-
stat is operating properly.
If continuity is not present as described, press the
reset button on the limit thermostat and repeat step
#3.
After repeating step #3 and no continuity is shown,
replace the limit thermostat.
FIG. 8 LIMIT THERMOSTAT
22978.0000
TL5
TL4
TL3
TL2
TL1
J1
1 2 3 4 5 6
P2230
P833
FIG. 9 LIMIT THERMOSTAT TERMINALS
BLK to Terminal
Block (Black Insert)
Block (Black Insert)
BLK to Tank
Heater (Left Terminal)
BLK to Contactor
Terminal
Heater (Left Terminal)
BLK to Contactor
Terminal
SERVICE (cont.)
LIMIT THERMOSTAT
Removal and Replacement:
1. Remove all wires from the limit thermostat termi-
1. Remove all wires from the limit thermostat termi-
nals.
2. Carefully remove the two #8-32 nuts securing the
limit thermostat to tank lid and remove limit ther-
mostat.
mostat.
3. Carefully secure new limit thermostat to tank lid.
4. Refer to Fig. 9 when reconnecting the wires.
4. Refer to Fig. 9 when reconnecting the wires.
28230 092200