SERVICE (cont.)
Location:
 
The contactor is located inside the front lower ac-
cess panel, left of center on the component bracket.
Test Procedures:
1.  Disconnect the brewer from the power source.
A. 10/08V and 10/40V THREE WIRE MODELS
 
Disconnect the black wire from the contactor coil 
to the limit thermostat and black wire from the 
white wire on the main harness.  
B. 08V  or  40V  TWO  WIRE  MODELS,  08V  and 
40V THREE WIRE MODELS
 
Disconnect the black wire from the contactor coil 
to the limit thermostat and black wire from the red 
wire on the main harness. 
C. 30V MODELS
 
Disconnect the red wire from contactor coil to the 
limit thermostat and the black wire from the main 
harness.
3.  Connect the brewer to the power source. 
4.  Check the voltage across the limit wire and the 
wire  from  the  the  main  harness.The  indication 
must be:
 
a) 10 volts for 10/08 and 10/40 volt, 3-wire 
with ground, single phase;
 
b) 30 volts for 30 volt, -wire with ground, single 
phase;
 
c) 08 volts for 08 volt, -wire with ground, single 
phase;
 
d) 40 volts for 40 volt, -wire with ground, single 
phase.
10067 040100
5.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described refer to the Wiring 
Diagrams and check the brewer wiring harness.
6.  Check for continuity between the black leads on 
the contactor coil or the left and right terminals 
on the contactor coil on 30 volt models.
If continuity is present as described, reconnect the 
wires and proceed to #7.
If continuity is not present as described, replace the 
contactor.
7.  On all brewers check the voltage across the upper 
left terminal and the upper right terminal on the 
contactor with a voltmeter. Connect the brewer to 
the power source. The indication must be:
 
a) 10 volts for 10/08 and 10/40 volt, 3-wire 
with ground, single phase;
 
b) 30 volts for 30 volt, -wire with ground, single 
phase;
 
c) 08 volts for 08 volt, -wire with ground, single 
phase;
 
d) 40 volts for 40 volt, -wire with ground, single 
phase.
8.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #9.
If voltage is not present as described, refer to the wiring 
diagrams and check the brewer wiring harness.
9.  Check for continuity across the terminals on the 
left side of the contactor by manually closing the 
contacts. Continuity must not be present when the 
contact is released.
10. Check for continuity across the terminals on the 
right side of the contactor by manually closing the 
contacts. Continuity must not be present when the 
contact is released.
If continuity is present as described, the contactor is 
operating properly.
If continuity is not present as described, replace the 
contactor. 
 
 