SERVICE (cont.)
CONTROL THERMOSTAT
FIG. 6 CONTROL THERMOSTAT
P113.40
Location:
 
The control thermostat is mounted on the left front 
of the top component bracket.
Test Procedures:
1.  Disconnect the brewer from the power source.
.  Locate  the  thermostat  and  the  voltage  check 
points.
Model
10/08V & 
10/40V - 3-
wire w/ground
single phase
30V - -wire 
w/ground single
phase
08V or 40V - 
-wire w/ground
single phase
4.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wiring 
diagrams and check the brewer wiring harness.
5.  Disconnect the black or red wires from the control 
thermostat.
6.  Check for continuity across the terminals on the 
control thermostat with the control thermostat in 
the "ON" position (fully clockwise), continuity must 
not be present when the thermostat is in the "OFF" 
position (fully counterclockwise).
If continuity is present as described, the control ther-
mostat is operating properly.
If continuity is not present as described, replace the 
control thermostat.
Removal and Replacement:
1.  Disconnect  the  wires  from  the  control  thermo-
stat.
.  Remove the thermostat capillary bulb by firmly pull-
ing up on the capillary at the component bracket. This 
will disengage the grommet from the component 
bracket.
3.  Remove  the  #8-3  screw  securing  the  control 
thermostat and mounting bracket to the component 
bracket. Remove control thermostat and bracket as 
an assembly.
4.  Remove knob from control thermostat.
5.  Remove the two #6-3 screws securing the control 
thermostat  to  the  thermostat  mounting  bracket. 
Remove and discard thermostat.
6.  Install new control thermostat on thermostat mount-
ing bracket and secure with two #6-3 screw.
7.  Install knob on thermostat.
8.   Install  thermostat  and  mounting  bracket  on  the 
component bracket and secure with one #8-3
 
screw.
9.  Carefully bend the capillary tube so that the tube and 
bulb inside the brewer are in the vertical position. 
The tube should extend an additional 5.5", above 
the bulb into the brewer.
NOTE: The capillary tube must be clear of any electrical 
termination and not kinked.
10. Refer to Fig. 7 and reconnect the wires.
11. Adjust the control thermostat as required.
Check Voltage Across
Black  wire  on  therostat 
from main
harness to white wire
in terminal block.
Red wire on thermo-
stat from main
harness to black wire
in terminal block.
Black wire on thermo-
stat from main
harness to red wire in
the terminal block.
Voltage
10V
30V
08V or
40V
10067 040100
P1730
FIG. 7 CONTROL THERMOSTAT TERMINALS
BLK from Main Har-
ness (All Models Ex-
cept 30V CE Models
RED from Main 
Harness (30V CE 
Models)
BLK to Limit Thermostat 
(All Models Except 30V CE 
Models
RED to Limit Thermostat 
(30V CE Models)