SERVICE (cont.)
FUSE AND FUSE HOLDER (208V, 240V and 230V 
Two Wire Models)
Location:
 
The fuse and fuse holder are located on the rear of 
the urn behind the rear utility cover.
Test Procedures:
1.  Disconnect the brewer from the power source.
.  Remove the cap and fuse from the fuse holder.
3.  Remove fuse from the cap.
4.  Check for continuity through the fuse.
If continuity is present as described, reinstall the fuse, 
the fuse is operating properly.
If continuity is not present as described replace the 
fuse.
Removal and Replacement:
Fuse:
1.  Remove the cap from the fuse holder.
.  Remove fuse from the fuse holder, inspect, if blown 
discard.
3.  Install new 5 amp fuse in the fuse holder.
4.  Reinstall fuse holder cap.
FIG.8 FUSE AND FUSE HOLDER
P1.30
Fuse Holder:
1.  Disconnect  the  wires  from  the  rear  of  the  fuse 
holder.
.  Remove  the  nut  securing  the  fuse  holder  to  the 
component bracket.
3.  Push fuse holder through the hole in the component 
bracket.
4.  Install new fuse holder and fuse through the hole 
in the component bracket and secure with nut.
5.  Refer to Fig. 9 and reconnect the wires.
P11
BLK from Main Harness (08V 
and 40V Two Wire Models)
RED from Main Harness
(30V Two Wire Models)
10067 040100
BLK    from  ON/OFF    Switch 
(08V  and  40V  Two  Wire 
Models)
RED  from  ON/OFF  Switch 
(30V Two Wire Models)
FIG. 9 FUSE HOLDER  TERMINALS