Bunn SRU Guía Del Usuario

Descargar
Página de 36
Page 1
SERVICE (cont.)
LIQUID LEVEL BOARD AND LEVEL PROBE (cont.)
T1 BLU to Solenoid Valve
T BLK to ON/OFF Switch (All models 
except 30V-CE models- RED on CE 
Models)
T3 WHI to Main Harness
(10/08V and10/40V 
models)
T3 RED to Main Harness
(08V, 40V single phase and 
three phase models)
T3 BLK  to Main Harness
(30V two wire models)
T4 PIN to Level Probe
FIG.13 LIQUID LEVEL BOARD TERMINALS
P1733
 Voltage - 
Jumper
Not Touching
Frame
Model
10/08V &
10/40V - 3-
wire w/ground
single phase
30V - -wire
w/ground
single phase
08V or 40V -
-wire  w/ground
single phase
Voltage -
Jumper
Touching
Frame
0
0
0
0
10067 040100
14. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the level 
probe, the liquid level board and level probe are oper-
ating properly.
If voltage is not present as described, check the pink wire 
on the level probe from liquid level board terminal.
Removal and Replacement:
1.  Remove all wires from the liquid level board.
.  Remove the #10-3 screw and flat washer securing 
the protective shield to the component bracket.
3.  Remove  the  #10-3  screw  and  internal  tooth 
lockwasher securing the liquid level board to the 
component bracket.
4.  Remove liquid level board and discard.
5.  Install new liquid level board on component bracket 
and secure with a #10-3 screw and internal tooth 
lockwasher.
6.  Install  protective  shield  and  secure  with  #10-3 
screw and flat washer.
7.  Refer to Fig. 13 and reconnect the wires.
8.  Disconnect the brewer from the power source and 
remove the jumper wire from T4.
If voltage is present as described, liquid level board is 
operating properly, proceed to #9.
If voltage is not present as described, replace the liquid 
level board.
9.  Reconnect the pink wire to T4.
10. Remove the two #8-3 screws securing the level 
probe to the component bracket.
11. Gently pull the probe out of the component bracket 
and inspect for corrosion. Replace if necessary.
1  Place the probe so that neither end is in contact 
with any metal surface of the brewer.
13. Connect the brewer to the power source. Check 
the voltage across T1 and T3, refer to chart below. 
Keep in mind there is an approximate delay of five 
seconds for output to stabilize.
10V
30V
08V or
40V