Bunn U3 Manuales De Servicio

Descargar
Página de 41
Page 3
SERVICE (cont.)
TIMER (Early Models)(cont.)
5.  With  a  voltmeter,  check  the  voltage  across  the 
sockets P1 and P (blue and white wires) of the 
female connector on the main harness when the 
"ON/OFF"  switch  is  in  the  "ON"  (upper)  position 
and the start switch pressed. Connect the brewer 
to the power source. The indication must be: 
 
a) 10 volts ac for three wire 10/08 volt, 10/40 
volt, 380 volt models and 08 or 40 volt ac for 
four wire 440 volt models.
 
b) 08 volts ac for two and three wire 08 volt 
models.
 
c) 40 volts ac for two and three wire 40 volt 
models.
 
d) 30 volts ac for two wire 30 volt CE models.
6.  Disconnect the brewer from the power source.
7.  Reconnect the three pin connector from the main 
wiring harness to the connector on the timer.
If voltage is present as described, proceed to #8.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
8.  Disconnect  the  black  and  white  wires  to  the 
pump.
9.  With  a  voltmeter,  check  the  voltage  across  the 
black and white wires when the "ON/OFF" switch 
is in the "ON" (upper) position and the start switch 
pressed to the start position and released. Connect 
the brewer to the power source. The indication 
must be:
 
a) 10 volts ac for three wire 10/08 volt, 10/40 
volt, 380 volt and 08 or 40 volt ac for four wire 
440 volt models.
 
b) 08 volts ac for two and three wire 08 volt 
models.
 
c) 40 volts ac for two and three wire 40 volt 
models.
 
d) 30 volts ac for two wire 30 volt CE models.
If voltage is present as described, the brew timer is 
operating properly. Reset the timer dial as required, 
to obtain the desired brew volume.
If  voltage  is  not  present  as  described,  replace  the 
timer.
Removal and Replacement:
1.  Separate all connectors between the brewer wiring 
harness and the timer.
.  Disconnect  the  timer  leads  from  the  pump 
leads.
3.  Remove the two #8-3 screws securing the brew 
timer  to  the  component  bracket  and  remove 
timer.
4.  Install new timer circuit board as described in Late 
Model Timer section on the following pages.
5.  Refer to Fig. 33 to reconnect the wires.
6.  Install the Timer Setting  Decal, provided with the 
timer  replacement  kit,  on  the  back  of  the  front 
access panel.
7.  Adjust the timer as required. Refer to Late Model 
Timer section on the following pages.
To Three Pin Female
Connector on Main
Harness
BLK to Pump
Lead
WHI to Pump Lead
Three Pin Connector from
 Half/Full Batch Switch
FIG. 31 TIMER TERMINALS
P1751
10060  080900
OLD STYLE