DIGITAL TIMER (Late Models)
J2
SET
     L
OC
K
LO
C
K
SE
T
TL
1
TL
2
TL
3
TL
4
TL
5
J1
FIG. 3  DIGITAL TIMER
P09.60
SERVICE (cont.)
Location:
 
The  timer  is  located  on  the  front  center  of  the 
component bracket.
Test Procedure.
NOTE: Do not remove or install wires while timer board 
is installed. Pressure applied to one side may cause 
damage to the board.
1.  Disconnect the brewer from the power source.
.  Remove  the  two  #8-3  screws  securing  circuit 
board to the mounting bracket.
3.  Remove circuit board and spacers (as required).
4.  With a voltmeter, check the voltage across terminals 
TL1 and TL when the "ON/OFF" switch is in the 
"ON" position. Connect the brewer to the power 
source. The indication must be:
 
a) 10 volts ac for three wire 10/08 volt , 10/40 
volt and 380 volt models.
 
b) 08 volts ac for two wire 08 volt models.
 
c) 40 volts ac for two wire 40 volt models.
 
d) 30 volts ac for two wire 30 volt CE models.
 
e) 08 or 40 volts ac for four wire 440 volt mod-
els.
 
5.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
6.  With a voltmeter, check the voltage across terminals 
TL1 and TL4 when the "ON/OFF" switch is in the 
"ON" position. Connect the brewer to the power 
source. The indication must be 0 volts.
If voltage is as described, proceed to #7.
If voltage is not as described, disconnect the brewer 
from the power source and replace the timer.
7.  With  a  voltmeter,  check  the  voltage  across  ter-
minals  TL1  and  TL4  when  the  "ON/OFF"  switch 
is in the "ON" position. Connect the brewer to the 
power source and press the "START" switch. The 
indication must be as follows:
 
a) 10 volts ac for three wire 10/08 volt, 10/40 
volt and 380 volt models.
 
b) 08 volts ac for two wire 08 volt models.
 
c) 40 volts ac for two wire 40 volt models.
 
d) 30 volts ac for two wire 30 volt CE models.
 
e) 08 or 40 volts ac for four wire 440 volt mod-
els.
If voltage is present as described, the brew timer is 
operating  properly.  Reset  the  timer  as  required,  to 
obtain the desired brew volume.
If voltage is not present as described, disconnect the 
brewer from the power source and replace the timer.
Removal and Replacement:
1.  Remove  the  two  #8-3  screws  securing  circuit 
board to the mounting bracket.
.  Remove circuit board and spacers (as required).
3.  Remove all wires from the timer.
4.  Attach all wires to the replacement timer board 
prior to installation to the component mounting 
bracket.  Refer to FIG. 33 when reconnecting the 
wires.
5.  Install new circuit board with spacers (as required) 
to the component mounting bracket.
6.  Adjust the timer as described below.
Timer Setting:
NOTE: Prior to setting or modifying volumes, check 
that  the  brewer  is  connected  to  water  supply,  the 
tank is properly filled, and a funnel and server are in 
place.
10060  080900