5.  Disconnect the wires on the ON/OFF switch.
6.  a)  10/08V,  10/40V,  08V,  40V,  380V  and 
440V  Models  -  Check  for  continuity  across  the 
terminals on the rear of the switch with the switch 
in the "ON" (upper) position. Continuity must not 
be present when the switch is in the "OFF" (lower) 
position.
 
b) 30V - CE Models - Check for continuity across 
the center terminal () and the lower terminal (1) 
when the switch is in the "ON" (upper) position. 
Continuity must not present when the switch is in 
"OFF" (lower) position.
If  continuity  is  present  as  described,  the  switch  is 
operating properly.
If continuity is not present as described, replace the 
switch. 
Removal and Replacement:
1.  Remove the wires from the switch terminals.
.  Compress the clips on the back side of the switch 
mounting bracket and gently push the through the 
opening.
3.  Push the new switch into the opening and spread 
the clips to hold switch in the mounting bracket.
NOTE: ON 30V - CE models terminal (3) must be 
on the top.
4.  Refer to Fig. 15 and reconnect the wires.
BLK from Main  Harness
BLK to Start Switch, Brew 
Timer & Liuqid Level Board 
L
10/08V, 10/40V, 08V, 40V, 380V AND 440V 
MODELS
BLK from Main Harness
RED to Main Harness
RED to Start Switch, Brew 
Timer & Liquid Level Board
30V - CE Models
FIG. 15 ON/OFF SWITCH TERMINALS
P1735
SERVICE (cont.)
ON/OFF SWITCH 
J2
SET
     L
OC
K
LO
CK
SE
T
TL
1
TL
2
TL
3
TL
4
TL
5
J1
FIG.14 ON/OFF SWITCH
P09.60
Location:
 
The ON/OFF switch is located on the left side of the 
switch mounting bracket. The switch mounting bracket 
is mounted on the front of the component bracket.
Test Procedures:
1.  Disconnect the brewer from the power source.
.  a)10/08V,  10/40V,  08V  and  40V  Models 
Remove the black wire on the ON/OFF switch from 
the fuse holder or circuit breaker and the red wire 
on the power indicator light.
b)   380V and 440V Models - Remove the black wire 
on  the  ON/OFF  switch  from  the  fuse  holder  or 
circuit breaker and the white wire from the power 
indicator light.
 
c) 30V - CE Models - Remove the red wire on the 
ON/OFF switch from the fuse holder and the black 
wire on the power indicator light.
3.  Connect the brewer to the power source. With a 
voltmeter, check the voltage across the removed 
wires. The indication must be:
 
a) 10 volts ac for 10/08 volt, 10/40 volt and 
380 volt models.
 
b)  08  volts  ac  for  two  or  three  wire  08  volt 
models.
 
c) 40 volts ac for two wire 40 volt models prior to 
#U300004095 and three wire 40 volt models.
 
d)  30  volts  ac  for  two  wire  30  volt  models 
#U300004095 and up).
 
e) 08 or 40 volts ac for four wire 440 volt mod-
els.
4.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the wires 
and proceed to #5
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
10060  080900